File #: 120278    Version: 0 Name:
Type: Bill Status: ENACTED
File created: 4/12/2012 In control: Committee on Licenses and Inspections
On agenda: Final action: 6/21/2012
Title: Amending Title 4 of The Philadelphia Code, entitled "The Philadelphia Building Construction and Occupancy Code," by amending Subcode "F" ("The Philadelphia Fire Code"), by modifying a subsection allowing smoke alarms in existing one- and two-family dwellings to be solely battery powered, all under certain terms and conditions.
Sponsors: Councilmember Jones, Councilmember Henon, Councilmember Greenlee, Councilmember Kenney, Councilmember Johnson, Councilmember Bass, Councilmember Reynolds Brown
Indexes: BUILDING CODE
Code sections: Title 4 - THE PHILADELPHIA BUILDING CONSTRUCTION AND OCCUPANCY CODE
Attachments: 1. CertifiedCopy12027800.pdf
Title
Amending Title 4 of The Philadelphia Code, entitled "The Philadelphia Building Construction and Occupancy Code," by amending Subcode "F" ("The Philadelphia Fire Code"), by modifying a subsection allowing smoke alarms in existing one- and two-family dwellings to be solely battery powered, all under certain terms and conditions.

Body
THE COUNCIL OF THE CITY OF PHILADELPHIA HEREBY ORDAINS:

SECTION 1. Title 4 of The Philadelphia Code, entitled "The Philadelphia Building Construction and Occupancy Code," is hereby amended to read as follows:

TITLE 4. THE PHILADELPHIA BUILDING CONSTRUCTION
AND OCCUPANCY CODE

* * *

CHAPTER 4-200. TEXT OF SUBCODES

* * *

SUBCODE "F" (THE PHILADELPHIA FIRE CODE)

* * *

CHAPTER 46. CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS

* * *

SECTION F-4603 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

* * *

F-4603.7.3 Power source. Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection.

Exceptions:

1. Smoke alarms are permitted to be solely battery operated powered with 10-year non-removable (sealed) batteries in existing one- and two-family buildings built prior to January 1, 1988, where no construction is taking place.

2. Smoke alarms are permitted to be solely battery operated powered with 10-year non-removable (sealed) batteries in one- and two-family buildings that are not served from a commercial power source.

3. Smoke alarms are permitted to be solely battery operated powered with 10-year non-removab...

Click here for full text